AWSBDC - NetView/OpenView messages

This section lists error and warning NetView and OpenView messages that might be issued.

The message component code is BDC.

AWSBDC001E

Error in !1, calling !2, for !3, error: !4

AWSBDC002E

Error allocating space in !1, error: !2

AWSBDC003E

Unknown parent for !1, id=!2

AWSBDC004E

Unknown node for !1, ID=!2

AWSBDC005E

Unknown network for !1, ID=!2

AWSBDC006E

Unknown workstation for !1, ID=!2

AWSBDC007E

Unknown owner for !1, ID=!2

AWSBDC008E

Error in !1, calling !2, for !3, field !4, error: !5

AWSBDC009E

Error unknown case in !1, line=!2, value=!3

AWSBDC010E

Error in getpwuid in !1

AWSBDC011E

Error in snmp call in !1, for !2, error: !3

AWSBDC012E

Unknown proc !2 in !1: !2

AWSBDC013E

Unknown field !1: !2

AWSBDC101W

Openview is not running on this system: !1

AWSBDC102E

HCL Workload Automation is not correctly installed on this system: "computer".

The program has found an error or inconsistency in the installation of HCL Workload Automation.

The program stops.

The HCL Workload Automation component installed on the indicated computer must be reinstalled.

AWSBDC103E

Initialization failed.

AWSBDC104E

No object for !1.

AWSBDC105E

Non-valid state packet received: !1

AWSBDC106E

Non-valid info packet received: !1

AWSBDC107E

Non-valid info count, doing !1: !2

AWSBDC108E

Non-valid info obj, doing !1, count !2: !3

AWSBDC109E

Non-valid definition packet received: !1

AWSBDC110E

Non-valid definition, doing !1: !2

AWSBDC112E

Non-valid process !2(!3) in !1

AWSBDC113E

Non-valid workstation !2(!3) in !1

AWSBDC150E

Can not send request !1 to demon: !2

AWSBDC205E

Initialization failed.

AWSBDC206E

Error opening !1, error: !2

AWSBDC207E

Error returned from select operation: !1

AWSBDC208E

Error opening snmp connection to !1: !2

AWSBDC209E

Error in !1, invalid packet: !2

AWSBDC210E

Error in sigact: !1

AWSBDC211E

Invalid request: !1

AWSBDC212E

Invalid packet, doing !1: !2

AWSBDC213E

Invalid type, doing !1: !2

AWSBDC214E

Invalid trap.

AWSBDC217E

Error adjusting oid for !1, oid=!2.

AWSBDC305E

Initialization failed.

AWSBDC306E

Error opening !1, error: !2

AWSBDC307E

Error returned from select operation: !1

AWSBDC308W

Process does not have a pid: !1

AWSBDC309E

Process has a non-valid pid: !1

AWSBDC310E

Error writing !2 to !1: !3

AWSBDC311E

Error sigaction: !1

AWSBDC312E

Non-valid trap: !1

AWSBDC313E

Non-valid data for trap !1: !2

AWSBDC314E

Unknown workstation !2 for trap !1

AWSBDC315E

Error opening !1: !2

AWSBDC316E

Timeout occurred while trying to check connection to !1

AWSBDC500E

not string

AWSBDC501E

bad length

AWSBDC502E

not print %x

AWSBDC503E

need error message for work != node