Extended minidump data set (XDUMP)
- 64-bit storage pages
- Application storage that is not directly involved with essential aspects of the analysis, such as program linkage or the point of failure
Z Abend Investigator requires an XDUMP data set to save 64-bit storage pages and associate them with a fault entry. 64-bit storage pages are not included in a minidump.
For 24-bit and 31-bit applications, an XDUMP data set can provide relief from re-analysis storage constraints and reduce the likelihood of minidump suppression when the MaxMinidumpPages value is exceeded. (See MaxMinidumpPages.)
To enable Z Abend Investigator to allocate an XDUMP data set,
specify a valid data set name pattern in the XDUMPDSN setting of the HFZOPTLM configuration-options module. See Specifying the extended minidump data set name pattern (XDUMPDSN). Z Abend Investigator
allocates the data set with RECFM=FBS LRECL=4096
and uses the access authorization
mechanism described in Managing XDUMP data set access. If
XDUMP data set allocation fails, Z Abend Investigator issues
message HFZ0184W.
An XDUMP data set is automatically deleted when its associated fault entry is deleted.