Modify CPWS arguments

When you are modifying a current plan workstation, the WSNAME argument is required; it identifies the workstation. The remaining arguments contain the modified information.

Table 1. Modify CPWS Arguments
Arg names Length Data type Description
ALTWS 4 Char When the workstation is set to failed or offline then another workstation can be specified for rerouting. Specify ALTWS if operations should be rerouted; if ALTWS is not supplied then no rerouting takes place.
Note: For virtual workstations, the argument is ignored.
PSC 1 Char Control on parallel server.
Note: For virtual workstations, the argument is ignored.
R1C 1 Char Control on resource 1.
Note: For virtual workstations, the argument is ignored.
R2C 1 Char Control on resource 2.
Note: For virtual workstations, the argument is ignored.
STARTACT 1 Char Action to be taken on current plan operations that have a status of started when the workstation status is set to failed or offline. Values are restart (R), set to error (E), or leave operation as is (L).
Note: If the STARTACT argument is omitted when a workstation is set to failed or offline then no action is performed on the operations, as though STARTACT L was specified.
STATUS 1 Char New status of active (A), failed (F), or offline (O).
WSNAME 4 Char Workstation name
WSREP 1 Char Workstation reporting attribute.
Note: For virtual workstations, the argument is ignored.