Verifying job submission
When HCL Workload Automation for Z submits
work, a submit event is written to the event
data set. A submit event is prefixed with an I, and can be one of
these:
- IJ1
- Job JCL. A job has been submitted.
- IJ2
- Started-task JCL. A started task has been started.
- IWTO
- An operation has been initiated for a general workstation with the WTO option. The submit task causes message EQQW775I to be issued.
To
perform this test for all type I events, start an operation
on each of three workstations, all of which specify the destination
of the system you are testing. The workstations must be a computer
automatic workstation for IJ1 events, a computer automatic workstation
with the started-task option for IJ2 events, and a general WTO workstation
for IWTO events. Follow this procedure to verify workload submission:
- Ensure that you have the correct workstations specified in the workstation description database.
- Create a test application with an operation for each workstation you want to test, and add it to the current plan.
- When the application has completed, browse the event data set, and verify that the required type I events have been created.
- If the operations are not started, check that the workstation status is ACTIVE and that the workstation is not WAITING FOR CONNECTION, which means that the controller is waiting for the corresponding tracker to communicate.