Dynamic Workload Console 10.1 Fix Pack 5 Readme File

Date
July, 2024
Fix Pack Name
10.1.0-HCL-DWC-FP0005
Product
Dynamic Workload Console 10.1.0.05
General Description
Dynamic Workload Console Fix Pack 5 for Version 10.1.0

This readme file is the most current information for the Fix Pack and takes precedence over all other documentation for Dynamic Workload Console version 10.1.0.

The most up-to-date version of this readme can be accessed at the following URL: Fix Pack readmes.

It is divided into the following sections:

Features introduced with Fix Pack 5

Changed features and feature capabilities

APARs and defects fixed in Fix Pack 5

Known limitations and workarounds

Resolved Common Vulnerabilities and Exposures (CVE)

Fix pack structure

Installing the Fix Pack

Documentation updates

Contacting HCL Software Support

Notices

Features introduced with Fix Pack 5

For more information about new features introduced with Fix Pack 5, see Summary of enhancements.

Changed features and feature capabilities

Supported WebSphere Application Server Liberty Base versions

HCL Workload Automation 10.1 Fix Pack 5 was formally tested by using WebSphere Application Server Liberty Base 24.0.0.6

Updated OpenSSL libraries

HCL Workload Automation 10.1 Fix Pack 5 has been updated with OpenSSL libraries version to 1.1.1.24 (means 1.1.1x).

OpenJDK Runtime Environment

HCL Workload Automation10.1 Fix Pack 5 has been updated with OpenJDK "11.0.22" 2024-01-16.

OpenJ9

HCL Workload Automation 10.1 Fix Pack 5 has been updated with OpenJ9 0.43.0

Updated JDBC drivers

HCL Workload Automation 10.1 Fix Pack 5 has been updated with Updated JDBC drivers for:
  • Derby: 10.15

DB2

HCL Workload Automation 10.1 Fix Pack 5 has been tested with DB2 Standard Edition 11.5.9.

MSSQL

HCL Workload Automation 10.1 Fix Pack 5 has been tested with MSSQL 2022.

Oracle

HCL Workload Automation 10.1 Fix Pack 5 has been tested with Oracle Database 23ai.

PeopleSoft PeopleTools

HCL Workload Automation 10.1 Fix Pack 5 has been tested with PeopleSoft PeopleTools 8.61.

SAP Remote Function Call

HCL Workload Automation 10.1 Fix Pack 5 has been tested with SAP RFC 7.50 Patch Level 13.

IBM Semeru Runtimes

HCL Workload Automation 10.1 Fix Pack 5 has been tested with IBM Semeru Runtime Open Edition 11.0.22.0

APARs and defects fixed in Fix Pack 5

This section lists APARs resolved in Fix Pack 5.

Table 1. APARs addressed in Fix Pack 5
APAR ABSTRACT
IJ10505 AWSJCO005E OCCURS WHEN TESTING CONNECTION TO MASTER DOMAIN MANAGER FROM DYNAMIC WORKLOAD CONSOLE.
IJ35160 UNABLE TO DELETE USER USING "TRASH BIN" ICON IN DYNAMIC WORKLOAD CONSOLE V9.5 FIX PACK 3.
IJ39281 UNABLE TO ADD SPECIAL RESOURCE DINAMICALLY TO JOBS IN CURRENT PLAN USING DYNAMIC WORKLOAD CONSOLE
IJ41104 UNABLE TO CHANGE DATA COLORS FOR NEWLY CREATED A DASHBOARD THAT MONITORS THE STATUS OF JOBS ALL COLUMNS HAVE THE SAME COLOR.
IJ41689 DYNAMIC WORKLOAD CONSOLE IS WRONG ALLOWING TO SUBMIT THE JOB: THE USER DID NOT HAVE ACCESS TO FOLDER1 BUT DYNAMIC WORKLOAD CONSOLE IS ABLE TO SUBMIT JOB.
IJ44428 PREDEFINED JOB RUN HISTORY REPORT COLUMN HEADER ISSUE.
IJ44722 BLANK PAGES WHEN BROWSING THROUGH THE DYNAMIC WORKLOAD CONSOLE AFTER HAVING SETUP A WILDCARD CERTIFICATE.
IJ46721 VALUE OF ITEM PER PAGE SECTION UNDER MANAGE DATASOURCES.
IJ47308 THIS.STDLIST VARIABLE IS NOT A VALID EXPRESSION IN DYNAMIC WORKLOAD CONSOLE V9.5 FIX PACK 6.
IJ47835 UNABLE TO DELETE ID FROM THE MANAGE RESOURCE PANEL.
IJ48251 PRIORITY NOT TAKEN INTO ACCOUNT WHEN SUBMITTING A STREAM WITHOUT USING SEARCH.
IJ48275 EDITING AND SAVING OWN REPORT AUTOMATICALLY CHANGES THE SHARED FIELD.
IJ48276 CHANGE THE REPORT THE OWNER BY OTHER USER WILL NOT BE SAVED, UNLESS OK BUTTON HAS BEEN CLICKED FROM THE PROMPT.
IJ48345 REMOVING BLANK ACCESS CONTROL LIST RECORD IN DYNAMIC WORKLOAD CONSOLE CAUSES ISSUES.
IJ48808 EARLIEST START FOR TIME RESTRICTIONS FOR A JOB STREAM, ON THE WORKLOAD DESIGNER IS ALWAYS SAVED AS "AM", EVEN IF YOU SPECIFY "PM".
IJ49003 RESOLUTION CRITERIA SET TO "CLOSEST PRECEDING" RETURNS TO "USER DEFAULT" AFTER SAVING AND RELOADING A JOB STREAM INTO DYNAMIC WORKLOAD CONSOLE.
IJ49007 NOT ABLE TO VIEW JOBS OR WORKSTATION STATUS IN WORKLOAD MONITOR FROM ARCHIVE PLAN.
IJ49049 DYNAMIC WORKLOAD CONSOLE SETTING MONITORMAXOBJECTSPM DOES NOT TAKE EFFECT FOR QUERY JOBS OF THE CURRENT PLAN.
IJ49113 PROBLEM OCCURS WITH GOOGLE CHROME WITH ADD JOBS WHEN CREATING A JOB STREAM.
IJ49115 REFLECTED XSS.
IJ49132 DYANMIC WORKLOAD CONSOLE SORT ON TYPE CAUSES DOMAIN MANAGERS TO DISAPPEAR.
IJ49167 JOBS FROM SAP ABENDS WHEN JOBID IS ENDING AS ALPHANUMERIC IN DYANMIC WORKLOAD CONSOLE.
IJ49217 LOGGING INTO DYANMIC WORKLOAD CONSOLE WITH SPECIFIED USER FAILS WITHOUT ANY ERROR MESSAGE IN BROWSER.
IJ49229 DBCS VARIABLE CAN NOT BE ADDED IN DYANMIC WORKLOAD CONSOLE.
IJ49484 JOBS THAT COMPLETE IN LESS THAN ONE MINUTE ARE NOT REPORTED IN CONMAN CLI, DYANMIC WORKLOAD CONSOLE, AND JOBRUNHISTORY REPORT.
IJ49510 UNABLE TO CREATE,SAVE AND DELETE A TASK IN DYANMIC WORKLOAD CONSOLE.
IJ49535 JOB STREAM NAME AND TIMESTAMP ARE NOT DISPLAYED FROM THE POP-UP SCREEN THAT APPEARS WHEN SUBMITTING A PREDEFINED JOB STREAM INTO CURRENT PLAN.
IJ49588 BATCH CANCELLATION STREAM VIA DYNAMIC WORKLOAD CONSOLE WILL HAVE THE USER LOGOUT AUTOMATICALLY AFTER RUNNING FOR SOME MINUTES.
IJ49589 THE UPLOADED FILE IS NOT A VALID WORKLOAD APPLICATION TEMPLATE.
IJ49679 CUSTOMER IS NOT ABLE TO CHANGE THE EARLIEST START TIME ON DYANMIC WORKLOAD CONSOLE DIRECTLY WHERE DYANMIC WORKLOAD CONSOLE 10.1 IS CONNECTED TO Z/OS MASTER DOMAIN MANAGER.
IJ49789 IF YOU TRY TO DELETE ONE JOB FROM JOB STREAM ALL OTHER JOBS ARE GETTING DELETED AND JOB STREAM WILL REMAIN EMPTY.
IJ49867 VULNERABILITY IN JACKSON (PRISMA-2023-0067)
IJ49910 DYNAMIC WORKLOAD CONSOLE PORT 9443 IS FLAGGED WITH VULNERABILITY HSTS MISSING FROM HTTPS SERVER.
IJ49923 REPORTS CREATED UNDER "MANAGE PRE-DEFINED REPORTS" TAB IS DISAPPEARING WHEN TRYING TO MODIFY AND SAVE IT.
IJ50017 IN V10.1 FIX PACK 4 DYNAMIC WORKLOAD CONSOLE HELP OPTION IS NOT GETTING DISPLAYED IN JAPANESE.
IJ50081 SHOWALL RERUN INSTANCES ISSUE.
IJ50183 WHEN CREATING A JOB STREAM DEFINITION IN DYANMIC WORKLOAD CONSOLE (WORKLOAD DESIGNER), THE "APPLY TO EACH JOB" CHECKBOX CANNOT BE SELECTED.
IJ50248 CALENDAR OFFSET DOES NOT SAVE ON RUN CYCLE IN DYANMIC WORKLOAD CONSOLE WORKLOAD DESIGNER.
IJ50458 HYPERLINK ON BAR CHART WIDGET NOT WORKING IN DYANMIC WORKLOAD CONSOLE DASHBOARD.
IJ50623 DYNAMIC WORKLOAD CONSOLE OUTOFMEMORY ERROR WITH JAVACORE GENERATED.
IJ50645 DYANMIC WORKLOAD CONSOLE WORKLOAD DESIGNER LIMITS JOB OUTPUT CONDITION VALUE TO 22 BYTES.
IJ50650 DYANMIC WORKLOAD CONSOLE DOES NOT CACHE STATIC RESOURCES.
IJ50721 ISSUES WITH DYANMIC WORKLOAD CONSOLE FUNCTIONING AFTER IMPLEMENTING SMARTCARD AUTHENTICATION.
IJ50906 DYANMIC WORKLOAD CONSOLE ALLOWING CARRIAGE RETURN WHEN CREATING JOB DEFINITION.
IJ51025 UNABLE TO SELECT ACTIONS (FIELD DISABLE) FOR MINIMUM DURATION AND MAXIMUM DURATION.
IJ51209 NOT ABLE TO RETRIEVE SAP PROCESS CHAIN JOB FROM DYNAMIC WORKLOAD CONSOLE V10.1 FIX PACK 4.
IJ51274 WHEN A "PREPRODUCTION PLAN" I CREATED IN DYNAMIC WORKLOAD CONSOLE, THE DISPLAY OF THE YEAR PART IS INCORRECT.
IJ51393 CANNOT INPUT KOREAN CHARACTERS IN THE SCHEDULING OBJECT NAME.

Table 2. Defects addressed in Fix Pack 5
Defects ABSTRACT
WA-113738 Existing plan names are not displayed.
WA-123852 Monitor Operator Messages: unable to duplicate the copy of created operator messages for the second or more time.
WA-130299 Maximum / Minimum duration field malfunction.
WA-132098 10.1 Fix Pack 5 - Not able to connect Distributed engine - HCL build.
WA-132445 Creating SAP R3 job on dynamic agent raises an error in saving on both Dynamic Workload Console and composer.
WA-132532 Prompt and Resource: unable to duplicate the task name (both on Chrome and Firefox browsers).
WA-132534 File: unable to duplicate the task name from both Chrome and Firefox browsers.
WA-132634 Show plan view: the auto refresh option is not functioning properly (both on Chrome and Firefox browsers).

Resolved Common Vulnerabilities and Exposures (CVE)

The following CVEs have been resolved:
  • CVE-2022-31147
  • CVE-2022-48564
  • CVE-2023-25193
  • CVE-2023-43804
  • CVE-2023-45288
  • CVE-2023-45803
  • CVE-2023-5752
  • CVE-2024-0450
  • CVE-2024-35195
  • CVE-2024-37891

Known limitations and workarounds

The following are software limitations and workarounds that affect Dynamic Workload Console version 10.1.0 Fix Pack 5.

Enable Periodic Refresh value is not displayed for workstations in Monitor Workload page when using Google Chrome.
When editing a workstation query in Monitor Workload page, the Enable Periodic Refresh value is not displayed if you are using Google Chrome.
Workaround
To avoid the issue, you can perform the following workaround:
  1. Open the Monitor Workload page and select Workstation from the drop down menu.
  2. Click the Run button.
  3. Enable the automatic refresh of the results by clicking on the Set auto-refresh button.
  4. Specify a time for the refresh, and then click the Continue button.

Limited Clara features on V10.1 Fix Pack 5
Some Clara features are not available on Dynamic Workload Console V10.1 Fix Pack 5.
If you want to use all the existing Clara features, you must use a version of the Dynamic Workload Console that is at least 10.2.2.

Issue when restarting the POD on a Kubernetes-based environment.
When restarting the Dynamic Workload Console POD on a Kubernetes-based environment, an issue occurs and the Dynamic Workload Console url cannot be reached anymore.
Workaround
To overcome the issue, perform the following steps:
  1. Delete the PVC by running the command below:
    kubectl delete pvc data-<releasename>-waconsole-<releasename>-waconsole-0 -n <namespace>
  2. Delete the POD by running the command below:
    kubectl delete pod <releasename>-waconsole-0 -n <namespace>
You can completely avoid the issue by using a version of the Dynamic Workload Console that is at least 10.2.2.

Fix pack structure

This section describes the structure of the images contained in this Fix pack.

Fix Pack files available for HCL Workload Automation by using HCL License Portal

Table 3. Readme file and WebSphere Liberty package
Name Description
HWA_10.1.0.05_ReadMeFirst_DWC Readme file with download instructions
WEBSPHERE_LIBERTY_BASE 23.0.0.10 WebSphere Liberty application server

Table 4. Linux components
Name Description
HWA_10.1.0.05_DWC_LINUX_X86_64 Dynamic Workload Console 10.1.0.05 for Linux X86-64

Table 5. Linux components on Docker
Name Description
HWA_10.1.0.05_DOCKER_DWC_LINUX_X86_64 Dynamic Workload Console 10.1.0.05 for Linux X86-64 (Docker image)
HWA_10.1.0.05_DOCKER_DWC_LINUX_S390 Dynamic Workload Console 10.1.0.05 for Linux on IBM Z (Docker image)

Table 6. Windows components
Name Description
HWA_10.1.0.05_DWC_WINDOWS_X86_64 Dynamic Workload Console 10.1.0.05 for Windows X86-64

Table 7. z/OS components
Name Description
HWA_10.1.0.05_DWC_ZSYSTEM Dynamic Workload Console 10.1.0.05 for Z System

Table 8. DB2 components
Name Description
IBM_DB2_StandardEd_11.5.8_LNX IBM® DB2® Standard Edition - Restricted Use for Linux® 11.5 on AMD64 and Intel® EM64T systems (x64)
IBM_DB2_Activation_11.5.8 IBM® DB2® Standard Edition 11.5 - Restricted Use - Activation
IBM_DB2_StandardEd_11.5.8_WIN IBM® DB2® Standard Edition - Restricted Use 11.5 for Windows® on AMD64 and Intel® EM64T systems (x64)

Installing the Fix Pack

This section describes how to apply Fix Pack 5 to Dynamic Workload Console.

Before starting the installation, verify that:
  • The Dynamic Workload Console is active.
  • No user is connected to the Dynamic Workload Console to prevent the data related to their working session from being lost.
Installation Notes
Read this section thoroughly before installing this Fix Pack.

  • Before installing the Fix Pack, ensure you have installed the required prerequisite software. To obtain the latest information about software requirements for HCL Workload Automation, see Product Requirements.
  • Supported WebSphere Application Server Liberty Base versions
    The formal test phase was performed using WebSphere Liberty 24.0.0.6.
  • On UNIX systems only: Before installing either the Dynamic Workload Console version 9.5 or this Fix Pack, make sure that umask is set to 022. To verify that umask is set to the correct value, from a command prompt, run the umask command. If the value is different from 022, modify it by running the command:
    umask 022
Interoperability notes
Dynamic Workload Console version 10.1 Fix Pack 5 supports all product versions indicated in the Dynamic Workload Console version 10.1 Release Notes which can be accessed at the following link: Dynamic Workload Console Version 10.1 Release Notes.
Installation methods
When you install the Fix Pack, the installation path varies depending on the version level you have currently installed:

If necessary, you can also return to a previous product version level, as described in Returning the Dynamic Workload Console to a previous product version level.

Disk space requirements

Before starting the Fix Pack installation, ensure that you have the following space available in the file system. The values indicated in the table show the disk space required by the Dynamic Workload Console alone. For the disk space required by other components, see the relevant documentation.

For the most up-to-date information about disk space and memory requirements, see the Supported Hardware document in Product requirments.

Table 9. Disk space requirements for installing a Dynamic Workload Console Fix Pack
Operating System Installation directory Temporary directory
AIX® 2 GB 800 MB
Linux s390x 2 GB 800 MB
Linux x86-64 2 GB 800 MB
Windows 64 2,5 GB 1 GB
Note: In addition to the above disk space, the installation requires further 579 MB on /usr file system.

If the installation fails because of lack of free disk space, you must stop the installation, free space on your disk, and start the installation again.

Documentation updates

Any additions or changes to the documentation as a result of this Fix Pack have been integrated into the online product documentation available in HCL Workload Automation documentation.

Contacting HCL Software Support

https://support.hcltechsw.com/csm

Refer to the HCL Workload Automation Support page: https://www.hcltech.com/products-and-platforms#support

Notices

This information was developed for products and services offered in the US. This material might be available from HCL in other languages. However, you may be required to own a copy of the product or product version in that language in order to access it.

HCL may not offer the products, services, or features discussed in this document in other countries. Consult your local HCL representative for information on the products and services currently available in your area. Any reference to an HCL product, program, or service is not intended to state or imply that only that HCL product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any HCL intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any non-HCL product, program, or service.

HCL may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not grant you any license to these patents. You can send license inquiries, in writing, to:

HCL
330 Potrero Ave.
Sunnyvale, CA 94085
USA
Attention: Office of the General Counsel

For license inquiries regarding double-byte character set (DBCS) information, contact the HCL Intellectual Property Department in your country or send inquiries, in writing, to:

HCL
330 Potrero Ave.
Sunnyvale, CA 94085
USA
Attention: Office of the General Counsel

HCL TECHNOLOGIES LTD. PROVIDES THIS PUBLICATION "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some jurisdictions do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you.

This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. HCL may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice.

Any references in this information to non-HCL websites are provided for convenience only and do not in any manner serve as an endorsement of those websites. The materials at those websites are not part of the materials for this HCL product and use of those websites is at your own risk.

HCL may use or distribute any of the information you provide in any way it believes appropriate without incurring any obligation to you.

Licensees of this program who wish to have information about it for the purpose of enabling: (i) the exchange of information between independently created programs and other programs (including this one) and (ii) the mutual use of the information which has been exchanged, should contact:

HCL
330 Potrero Ave.
Sunnyvale, CA 94085
USA
Attention: Office of the General Counsel

Such information may be available, subject to appropriate terms and conditions, including in some cases, payment of a fee.

The licensed program described in this document and all licensed material available for it are provided by HCL under terms of the HCL Customer Agreement, HCL International Program License Agreement or any equivalent agreement between us.

The performance data discussed herein is presented as derived under specific operating conditions. Actual results may vary.

Information concerning non-HCL products was obtained from the suppliers of those products, their published announcements or other publicly available sources. HCL has not tested those products and cannot confirm the accuracy of performance, compatibility or any other claims related to non-HCL products. Questions on the capabilities of non-HCL products should be addressed to the suppliers of those products.

This information is for planning purposes only. The information herein is subject to change before the products described become available.

This information contains examples of data and reports used in daily business operations. To illustrate them as completely as possible, the examples include the names of individuals, companies, brands, and products. All of these names are fictitious and any similarity to actual people or business enterprises is entirely coincidental.

COPYRIGHT LICENSE:

This information contains sample application programs in source language, which illustrate programming techniques on various operating platforms. You may copy, modify, and distribute these sample programs in any form without payment to HCL, for the purposes of developing, using, marketing or distributing application programs conforming to the application programming interface for the operating platform for which the sample programs are written. These examples have not been thoroughly tested under all conditions. HCL, therefore, cannot guarantee or imply reliability, serviceability, or function of these programs. The sample programs are provided "AS IS", without warranty of any kind. HCL shall not be liable for any damages arising out of your use of the sample programs.

© (HCL) (2023).
Portions of this code are derived from HCL Sample Programs.
© Copyright HCL Ltd. _2023_.

Trademarks

HCL, and other HCL graphics, logos, and service names including "hcltech.com" are trademarks of HCL. Except as specifically permitted herein, these Trademarks may not be used without the prior written permission from HCL. All other trademarks not owned by HCL that appear on this website are the property of their respective owners, who may or may not be affiliated with, connected to, or sponsored by HCL.

Adobe, the Adobe logo, PostScript, and the PostScript logo are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States, and/or other countries.

IT Infrastructure Library is a Registered Trade Mark of AXELOS Limited.

Linear Tape-Open, LTO, the LTO Logo, Ultrium, and the Ultrium logo are trademarks of HP, IBM® Corp. and Quantum in the U.S. and other countries.

Intel, Intel logo, Intel Inside, Intel Inside logo, Intel Centrino, Intel Centrino logo, Celeron, Intel Xeon, Intel SpeedStep, Itanium, and Pentium are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.

Linux is a registered trademark of Linus Torvalds in the United States, other countries, or both.

Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both.


Java Logo
Java and all Java-based trademarks and logos are trademarks or registered trademarks of Oracle and/or its affiliates.

Cell Broadband Engine is a trademark of Sony Computer Entertainment, Inc. in the United States, other countries, or both and is used under license therefrom.

ITIL is a Registered Trade Mark of AXELOS Limited.

UNIX is a registered trademark of The Open Group in the United States and other countries.

Terms and conditions for product documentation
Permissions for the use of these publications are granted subject to the following terms and conditions.
Applicability
These terms and conditions are in addition to any terms of use for the HCL website.
Personal use
You may reproduce these publications for your personal, noncommercial use provided that all proprietary notices are preserved. You may not distribute, display or make derivative work of these publications, or any portion thereof, without the express consent of HCL.
Commercial use
You may reproduce, distribute and display these publications solely within your enterprise provided that all proprietary notices are preserved. You may not make derivative works of these publications, or reproduce, distribute or display these publications or any portion thereof outside your enterprise, without the express consent of HCL.
Rights

Except as expressly granted in this permission, no other permissions, licenses or rights are granted, either express or implied, to the publications or any information, data, software or other intellectual property contained therein.

HCL reserves the right to withdraw the permissions granted herein whenever, in its discretion, the use of the publications is detrimental to its interest or, as determined by HCL, the above instructions are not being properly followed.

You may not download, export or re-export this information except in full compliance with all applicable laws and regulations, including all United States export laws and regulations.

HCL MAKES NO GUARANTEE ABOUT THE CONTENT OF THESE PUBLICATIONS. THE PUBLICATIONS ARE PROVIDED "AS-IS" AND WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY, NON-INFRINGEMENT, AND FITNESS FOR A PARTICULAR PURPOSE.