Synchronizing scopes after syndication | HCL Digital Experience

To automatically run scope synchronization whenever syndication occurs, specify the tagging.syndication.enableTagSynchronization property in the Web Content Manager configuration service.

Procedure

  1. Log in to the WebSphere® Integrated Solutions Console (http://hostname.example.com:10027/ibm/console).
  2. Click Resources > Resource Environment > Resource Environment Providers.
  3. Click WCM WCMConfigService.
  4. Under Additional Properties, click Custom Properties.
  5. Add the tagging.syndication.enableTagSynchronization property.
    1. Click New, and enter the property name tagging.syndication.enableTagSynchronization.
    2. Set the string value to true.
  6. Click OK, and save the changes to the master configuration.
  7. Restart the portal.