The abend code explanation header record in HFZHUSRM has the following format: Figure 1. Syntax
where
abend_code
A three-character prefix followed by a four-digit user abend code. It is not case-sensitive. For
example:
XYZ0001
prd1234
zzz0999
are all valid abend code specifications.
The three-character abend code prefix is used to identify the load module name in which the user
abend is issued. That is, the first 3 characters of the load module name in which the abend
occurred, must match the specified abend code prefix. This match permits the same user abend code to
be issued from different load modules, each potentially with its own unique explanation.
Note that :abend. must begin in column 1.
In the following example, two user abends are defined. The U1888 abend might be issued by a load
module whose name begins with the 3 characters MD1, for example MD100P. The U0016 abend might be
issued from a load module name whose name begins with the 3 characters EXT, for example EXTMAIN. The
HFZHUSRM specification follows:
:abend.MD1888
An error occurred when attempting to write the invoice
to DDname SYSPRINT.
:abend.EXT0016
Incorrect EXTRACT option specified.
The problem might be one of the following:
- Invalid range
- Typo
Respecify and try again.
When using the LOOKUP command, user-defined abend code explanations
appear in the "Abend Codes" main category, under the subcategory "Other
Abend Codes", and further separated into categories according to the
three character load module name prefix.