Verifying Z Abend Investigator customization under CICS
This section is applicable only if you have CICS® installed, and have completed the customization of CICS® as described in Customizing the CICS environment.
Having installed the CFA transaction, and the exits that you want, invoke the CFA
transaction from a CICS® terminal, and press PF9 to see the
following display:
Z Abend Investigator IVP Testing Options: S=Select IVP Description _ 0C1 in program HFZXFA _ EXEC CICS DUMP DUMPCODE(FAD1) - XDUREQ exit must be installed _ EXEC CICS ABEND ABCODE(FLT1) _ EXEC CICS ABEND ABCODE(FLT2) - LE Assembler Use S to Select the IVP to execute PF3=Exit ENTER=Execute
From here, type S next to the desired tests (note that the XDUREQ exit must be installed for the EXEC CICS® DUMP DUMPCODE(FAD1) test), and press Enter.
Since DeferredReport is the default option for CICS®, determine the history file name and fault ID for each IVP from the HFZ0003I messages, and then, using the Z Abend Investigator ISPF interface, issue the 'V' line command against each fault entry to view the saved report.