Submit/release data set (EQQSUDS)

The submit/release data set is device dependent and must have only a primary space allocation. Do not allocate any secondary space. The data set is formatted the first time it is used. Each time you use the data set, HCL Workload Automation for Z keeps a record of where to start. When the last track of the data set is written, HCL Workload Automation for Z starts writing on the first track again.

Two cylinders are enough at most installations.

Note:
  1. The first time HCL Workload Automation for Z is started with a newly allocated submit/release data set, an SD37 error occurs when it formats the data set. Expect this, do not treat it as an error.
  2. Do not move HCL Workload Automation for Z submit/release data sets once they are allocated. They contain device-dependent information and cannot be copied from one device type to another, or moved on the same volume. A submit/release data set that is moved will be re-initialized. This causes all information in the data set to be lost. If you have DFHSM or a similar product installed, define HCL Workload Automation for Z submit/release data sets so that they are not migrated or moved.