PLX parameter of the z/OS® UNIX® Inquisitor program

While the earlier discussion about the PLX parameter setting for the z/OS Inquisitor program is also broadly applicable to the z/OS UNIX Inquisitor, it is important to understand that using PLX=Y for one program does not imply that PLX=Y should be used for the other program.

For the z/OS Inquisitor (which scans PDS and PDSE libraries), PLX=Y should only be specified when all the relevant systems have access to all the same libraries, and for this it is usually sufficient to share the DASD and catalog configurations.

For the z/OS UNIX Inquisitor, PLX=Y should only be specified when all the relevant systems have access to all the same UNIX files. Sharing DASD and catalogs is not sufficient to achieve this. Systems in a sysplex must be explicitly configured to share the same UNIX file system before it is suitable to use the PLX=Y setting of the UNIX Inquisitor program.