SYSOUT archiving exit (EQQUX005)

EQQUX005 is called by the job completion checker (JCC) during processing of SYSOUT data sets for a job. The exit can be called several times for the same job as the JCC progresses through the various SYSOUT data sets.

This exit is commonly used to change the defined SYSOUT disposition, depending on the success or failure of the job. EQQUX005 is a tracker exit, although the success or failure of an operation is ultimately determined by the controller. The sample library SEQQSAMP that was created during installation contains the EQQX5ASM exit, which is a sample of SYSOUT archiving exits. For more information about this sample, see SYSOUT archiving exit.