EQQBT03 - EQQBT23

EQQBT03E

THE BACKUP CONTROLLER COMMUNICATION TASK FAILED TO INITIALIZE THE C PROCESS.

An error occurred while attaching a task to run the C code as an MVS executable program: an invocation to the BPX1ATM callable service failed.

The backup controller communication task initialization fails.

Try to restart the backup controller communication task with the modify command. If the problem persists, contact IBM Software Support.

EQQBT04W

THE BACKUP CONTROLLER COMMUNICATION TASK FAILED TO SET THE TCP/IP JOB NAME TO TCPNAME. THE DEFAULT TCPIP HAS BEEN USED.

An error occurred while trying to communicate with a TCP/IP stack with TCPIPJOBNAME TCPNAME.

The backup controller communication task uses the default name TCPIP.

Verify your TCP/IP stack configuration and make sure that the TCPIPJOBNAME parameter in the TCPOPTS or HTTPOPTS statement is correct.

EQQBT05W

TCP/IP CANNOT BE INITIALIZED. CHECK THAT TCP/IP IS AVAILABLE AND THAT SSL IS PROPERLY CONFIGURED.

The backup controller communication task got an error when trying to communicate with TCP/IP.

HCL Workload Automation for Z tries periodically to connect to TCP/IP.

Verify that TCP/IP is available and SSL is correctly configured.

EQQBT09E

AN ERROR OCCURRED IN TCP/IP CALL FUNC. RETURN CODE: RC ERRNO: ERRNO. DIAGNOSE TCP/IP MESSAGE FOLLOWS.

A socket call to TCP/IP with RC and ERRNO failed. The TCP/IP message follows.

The connection to TCP/IP is not established or reset. HCL Workload Automation for Z tries to reconnect indefinitely.

Verify that HCL Workload Automation for Z has established the connection. If the problem persists, contact IBM Software Support.

EQQBT14E

THE BACKUP CONTROLLER COMMUNICATION TASK HAS IGNORED THE FOLLOWING QUEUE ELEMENT: REQUEST.

The backup controller communication task received an invalid queue element. A queue element did not contain the correct eye catcher or version number.

The backup controller communication task does not process the invalid element, but continues normal processing.

Save the HCL Workload Automation for Z message log and contact IBM Software Support.

Contact your system programmer.

EQQBT15E

A SEVERE ERROR IN THE BACKUP CONTROLLER COMMUNICATION TASK HAS CAUSED ONE OR MORE REQUESTS TO BE LOST.

The backup controller communication task abended while processing elements on HTTQ because the queue chaining is invalid.

z/OS recovery/termination is requested to generate a dump. All elements on HTTQ are lost and the backup controller communication task terminates.

Save the message log and dump data set, and contact IBM Software Support.
Review the HCL Workload Automation for Z message log data set and the SYSMDUMP data set, to determine the cause of the problem.

EQQBT16E

THE BACKUP CONTROLLER COMMUNICATION TASK ABENDED WHILE PROCESSING THE FOLLOWING REQUEST: REQUEST.

An abend prevented the backup controller communication task from processing a queue element.

z/OS recovery/termination is requested to generate a dump. The backup controller communication task attempts to continue normal processing.

Save the HCL Workload Automation for Z message log and dump data set, and contact IBM Software Support.

Contact your system programmer.

Review the HCL Workload Automation for Z message log data set and the SYSMDUMP data set, to determine the cause of the problem.

EQQBT17E

CONNECTION RESET BY PEER.

The communication partner closed the connection.

HCL Workload Automation for Z periodically tries to establish the connection again.

None.

EQQBT23E

THE CONTROLLER CHECK ROLE PROCESS FAILED TO INITIALIZE THE C PROCESS.

An error occurred while attaching a task to run the C code as an MVS executable program: an invocation to the BPX1ATM callable service failed.

The controller initialization fails.

Try to restart the controller. If the problem persists, contact IBM Software Support.