Setting web access control connection properties in Unica
To configure web access control integration, you set some configuration properties.
Procedure
On the
page, set values of the properties as described in the following table.
See the related reference for details on how to set each property.
Property | Value |
---|---|
Unica | Unica Platform | Security | Login method details | Select Web access control. |
Unica | Unica Platform | Security | Login method details| Web access control | Additional header variables | Specified comma separated variables are looked up in HTTP header, while logging
through Web access control software. If audit log is enabled, these variables are captured
and stored in the Authentication event under Audit logs. The captured HTTP variables can
be seen by clicking "More" under "Event Details". Note: This property is available from
version 12.1.0.3 onwards. |
Unica | Unica Platform | Security | Login method details | Web access control | Username pattern | A Java™ regular expression used to extract the user login from the HTTP header variable in web access control software. You must XML-escape any XML characters in the regular expression. The recommended value for SiteMinder and IBM Security Access Manager is \w* |
Unica | Unica Platform | Security | Login method details | Web access control | Web access control header variable | The HTTP header variable configured in the web access control software, which is submitted to the web application server. By default, SiteMinder uses sm_user, and IBM Security Access Manager uses iv-user. For IBM Security Access Manager, set this value to the user name component of the IBM® Raw string, not the IBM® HTTP string. |
Unica | General | Navigation | Unica Platform URL | Set to http://sm_host:sm_port/sm_realm/unica
where
|