Deployment process failure
Symptoms
A deployment process fails to complete successfully.
The following error messages appear in the Streams log.
CDISR2517E The stdin mode is not the standard
input for prompting for a password. The tty mode is the standard input. The password prompt was
disabled.
CDISC5102E An error occurred while the system logged in to the instance. See the previous
error messages.
When you synchronize Streams by clicking Synchronize with changed Streams configuration on the page, you see this warning: "Connection refused."
Causes
The most likely cause is incorrect or missed execution of the Streams First Steps application.
Resolution:
- Log in to the Streams runtime server as the streamsadmin user.
- Execute the following command:
streamstool genkey
- Restart the Streams instance and redeploy the workspace.