After you change the Unica Deliver and Unica Campaign configurations,
you must restart the Unica Campaign web
application server, the Response and Contact Tracker (RCT), and the Unica Campaign listener.
Procedure
- Restart the web application server for Unica Campaign.
For instructions, see the documentation for your web application
server.
To verify that the server has started, log in to your Unica installation,
access Unica Campaign,
and confirm that you can open an existing mailing.
- Restart the Response and Contact Tracker (RCT).
To restart the RCT manually, run the rct script in the
bin directory under your Unica Deliver installation, as follows:
rct start.
To stop the RCT manually run the rct script in the
bin directory under your Unica Deliver installation, as follows:
rct stop.
If RCT is configured
to run as a service, restart the RCT service. The first time that
you restart the RCT as a service, you must manually restart the RCT
afterward.
For more information, see Unica Deliver Response and Contact Tracker (RCT) script.
- Restart the Unica Campaign listener:
- On Windows™, run the cmpServer.bat file
in the bin directory under your Unica Campaign installation.
- On UNIX™, run the following
command as root: ./rc.unica_ac start