Setting a time window for DAOS resynchronization

The Domino® administrator can specify when Domino Attachment and Object Service (DAOS) resynchronization should run on a server, so that peak production hours can be avoided.

About this task

If you do not want to schedule a specific time for resynchronization by using a Program document, you can set up a time window to specify whether or not resynchronization may run at a given time, and also tell it to stop at a specified stop time.

Procedure

  1. On the Domino server where DAOS is enabled, edit the NOTES.INI file.
  2. Add the following parameters and values. The format of the time is as follows: HH:MM:SS AM/PM.
    DAOS_RESYNC_START_TIME=time 
    DAOS_RESYNC_STOP_TIME=time
    For example:
    DAOS_RESYNC_START_TIME=12:00:00 AM 
    DAOS_RESYNC_STOP_TIME=04:00:00 AM