EQQO001 - EQQO011

EQQO001I

APPC TASK INITIALIZATION IS COMPLETE

The APPC task has completed initialization processing.

Processing continues.

None.

EQQO002E

APPC TASK ABENDED WHEN PROCESSING THE FOLLOWING QUEUE ELEMENT DQE

An abend prevented the APPC task from processing a queue element.

z/OS recovery/termination is requested to generate a dump. The APPC task attempts to continue normal processing.

Save the EQQMLOG, EQQDUMP, and system dump data sets and contact IBM Software Support.

Contact your system programmer.

Review the HCL Workload Automation for Z message log data set (EQQMLOG), the diagnostic data set (EQQDUMP), and the system dump data set to determine the cause of the error.

EQQO003E

APPC TASK INITIALIZATION FAILED - XCF FAILURE

The APPC task has ended due to an XCF failure or request denied by XCF.

The APPC task is not started.

None.

Make sure that the XCF destination names are defined correctly and restart the APPC task when XCF is available.

EQQO004E

APPC TASK INITIALIZATION FAILED - APPC/MVS FAILURE

The APPC task has ended due to APPC failure

The APPC task is not started.

Restart the APPC address space before starting the HCL Workload Automation for Z APPC task.

EQQO005I

INITIALIZATION FAILED - SUBSYSTEM STOP REQUESTED

A stop subsystem command was issued while the APPC task was initializing. This caused the task to end.

The HCL Workload Automation for Z subsystem continues the shutdown sequence.

None.

EQQO006E

APPC TASK TERMINATED - MVS/APPC SHUTTING DOWN

The APPC task has ended due to APPC ending. All active conversations have been lost.

The APPC task is shut down.

When APPC is available again, restart the HCL Workload Automation for Z APPC task.

EQQO007E

THE APPC TASK IGNORED THE FOLLOWING ELEMENT ON THE APPC QUEUE DQE

An invalid allocate request or outbound reply was found on the APPC queue.

Processing continues.

If the element was an allocate request from a user written transaction program (TP), verify the code in the TP. If not, search the IBM Support database for a solution at Support.

EQQO008E

THE APPC TASK IGNORED THE FOLLOWING INBOUND APPC BUFFER APP

An invalid buffer was received.

Processing continues.

If the element was an allocate request from a user written transaction program (TP), verify the code in the TP. If not, search the IBM Support database for a solution at Support.

EQQO009E

APPC TASK QUEUE POINTERS ARE DESTROYED, APPQ IS LOST

The APPC task abended while processing elements on APPQ because the queue chaining is invalid.

z/OS recovery/termination is requested to generate a dump. The APPC task attempts to continue normal processing.

Save the EQQMLOG, EQQDUMP, and system dump data sets and contact IBM Software Support.

Contact your system programmer.

Review the HCL Workload Automation for Z message log data set (EQQMLOG), the diagnostic data set (EQQDUMP), and the system dump data set to determine the cause of the error.

EQQO010E

AN APPC FUNCTION HAS BEEN REQUESTED BUT THE LEVEL OF THE MVS SYSTEM IS NOT MVS/SPP4.2.2 OR HIGHER

HCL Workload Automation for Z attempted to initialize APPC services, but due to the wrong operating system level, the attempt failed.

HCL Workload Automation for Z continues to initialize without APPC support.

Remove (or set to NO) the APPCTASK initialization statement.

Review the HCL Workload Automation for Z initialization statement.

EQQO011E

APPC/MVS INTERFACE MODULE COULD NOT BE LOADED

An APPC interface module was not found in the library search path.

HCL Workload Automation for Z continues, but the APPC functions as requested by the APPCTASK keyword are disabled.