Reset criteria for event patterns
You can specify the reset criteria for event patterns which is used to reset a pattern
after a visitor starts a session. When the event pattern is reset, the status is set to
False
and all counters are set to zero.
Use the Reset criteria tab in the Add event pattern window to specify the reset criteria. You can set only one criteria at a time.
The reset criteria is applicable only when the event pattern is active and the event pattern
status is not set to True
. If the status for the event pattern is set to
True
, the reset criteria does not apply. After the event pattern status is set to
True
, the event pattern remains in this state for 1 day or for the period specified
in Extend true state for additional (time). The event pattern status is then
set to False
again.
Setting the Reset criteria is optional. By default, the Reset criteria is set as None.
Reset criteria | Input | Description |
---|---|---|
None | No reset criteria is specified. | |
Inactivity | Specify time in Hours, Days, or Weeks. | Reset the event pattern if the visitor is inactive for the specified time. |
Periodic | Specify the following:
|
Reset every x number of days at the specified time of day, starting from the specified date. |
When an event occurs | Select the event. | When the selected event occurs, the event pattern is reset. The events available for
selection are events other than the ones that are selected for the event pattern definition on the
Pattern tab. Multiphase events are not supported. |